| Generator Model | GJY1500-NG | |
| Gas Source | Natural Gas | |
| Standby kVA | 2050 | |
| Prime kVA | 1875 | |
| Standby kW | 1640 | |
| Prime kW | 1500 | |
| Rpm | (r/min) | 1000 |
| Voltage Options | V | 400 – 3300 – 6000 – 6300 – 6600 – 10000 – 10500 – 11000 |
| Frequency | 50 | |
| Power Factor | 0.8 | |
| Electrical Efficiency | % | ≥40 |
| Thermal Efficiency | % | ≥51.8 |
| Total Efficiency | % | ≥91.8 |
| Gas Consumption | m³/h | 386.6 |
| Heat balance parameters | ||
| Cooling water heat of cylinder liner (±8%) | kW | 542 |
| Cooling water heat of oil cooler (±8%) | kW | 303 |
| Total cooling water heat of high temperature cooling system (±8%) | kW | 845 |
| Cooling water heat of intercooler (±8%) | kW | 369 |
| Total cooling water heat of low temperature cooling system (±8) | kW | 369 |
| Exhaust gas waste heat (exhaust gas temperature up to 120°C) (±8%) | kW | 887 |
| Total radiant heat (±8%) | kW | 118 |
| Cooling parameters | ||
| Flow rate of high temperature circulating water | m³/h | 72 |
| Inlet temperature of high temperature circulating water (±2%) | °C | 74.4 |
| Outlet temperature of high temperature circulating water (±2%) | °C | 86 |
| Low temperature inlet water temperature (±2%) | °C | 40 |
| Low temperature outlet water temperature (±2%) | °C | 45.1 |
| Intake and exhaust parameters | ||
| Air intake | kg/h | 7501.8 |
| Gas intake | kg/h | 305.2 |
| Air displacement | kg/h | 7807 |
| Exhaust temperature after turbocharger (±5%) | °C | 490 |
| Test Conditions | ||
| Calorific value of gas | kWh/m | 9.7 |
| Methane volume content | % | ≥96 |
| Gas temperature | °C | -10~40°C |
| Gas inlet pressure (Before regulator) | kPa | 30~50 |
| Gas inlet pressure (After regulator) | kPa | 8~15 |
| Air intake negative pressure | kPa | >-3 |
| Exhaust back pressure | kPa | <5 |
| Absolute atmospheric pressure | kPa | 101.32 |
| Ambient temperature | °C | 25 |
| Relative humidity | % | 30 |
| Altitude | m | ≤1,000 |