Generator Model | GJY350-NG | |
Gas Source | Natural Gas | |
Standby kVA | 480 | |
Prime kVA | 435 | |
Standby kW | 384 | |
Prime kW | 350 | |
RPM | (r/min) | 1500 |
Voltage Options | V | 400 |
Frequency | 50 | |
Power Factor | 0.8 | |
Electrical Efficiency | % | ≥38 |
Thermal Efficiency | % | ≥54.5 |
Total Efficiency | % | ≥92.5 |
Gas Consumption | m³/h | 101.2 |
Heat balance parameters | ||
Cylinder liner cooling water heat (±8%) | kW | 220 |
Oil cooler cooling water heat (±8%) | kW | 54 |
High temperature cooling system total cooling water heat (±8%) | kW | 275 |
Intercooler cooling water heat (±8%) | kW | 79 |
Low temperature cooling system total cooling water heat (±8%) | kW | 79 |
Exhaust gas waste heat (exhaust gas temperature up to 120°C) (±8%) | kW | 177 |
Total radiant heat (±8%) | kW | 30 |
Cooling parameters | ||
High temperature circulation water flow rate | m³/h | 48 |
High temperature circulation water inlet temperature (±2%) | °C | 80.1 |
High temperature circulation water outlet temperature (±2%) | °C | 85 |
Low temperature inlet water temperature (±2%) | °C | 40 |
Low temperature outlet water temperature (±2%) | °C | 42.3 |
Intake and exhaust parameters | ||
Air intake | kg/h | 1,807.3 |
Gas intake | kg/h | 70.7 |
Air displacement | kg/h | 1,878 |
Post-turbocharger exhaust temperature (±5%) | °C | 425 |
Test Conditions | ||
Calorific value of gas | kWh/m | 9.1 |
Methane volume content | % | ≥96 |
Gas temperature | °C | -10~40°C |
Gas Inlet Pressure (Before Regulator) | kPa | 800~1000 |
Gas Inlet Pressure (After Regulator) | kPa | 400~600 |
Air intake negative pressure | kPa | >-3 |
Exhaust back pressure | kPa | <5 |
Absolute atmospheric pressure | kPa | 101.32 |
Ambient temperature | °C | 25 |
Relative humidity | % | 30 |
Altitude | m | ≤1,000 |