Gucbir Jenerator produces the generators in Turkey accordance to European Quality Standards by focusing and targeting the top quality
Genset Brand | Gucbir Generator | |
Country of Origin | Turkey | |
Genset Model | GJL25 S | |
Standby Power | kVA | 25 |
Prime Power | kVA | 23 |
Frequency | Hz. | 50 |
Voltage | V | 230/400 |
Phase | 3 | |
Fuel | Diesel | |
Control Panel | Datakom GB500 |
Engine Brand | Lister Petter |
Engine Model | SA427G1 |
Model Series | Starlite |
Emission | Stage II |
Fuel Type | 4 Stroke – Diesel |
Injection Type and System | Indirect injection |
Aspiration | Naturally Aspirated |
Governor System | Elektronic |
Number of Cylinders | 4 |
Bore and Stroke | 90 x105 mm |
Total Displacement | 2,7 lt. |
Cooling System | Water Cooled |
Compression Ratio | 18.5:1 |
Fuel Consumption 50% PRP | 3,40 lt/s |
Fuel Consumption 75% PRP | 4,24 lt/s |
Fuel Consumption 100 % PRP | 5,76 lt/s |
Fuel Consumption Standby | 6,74 lt/s |
Total oil capacity | 8 lt. |
Total coolant capacityTotal coolant capacity | 9,8 lt. |
Maranello, Stamford and Leroy Somer are the brands of Alternator that you may choice with Perkins range.
Please download the data sheet in following documents link.
Standart Specifications |
Water cooled, Diesel engine |
Radiator with mechanical fan |
Protective grille for rotating and hot parts |
Electric starter and charge alternator |
Starting battery (with lead acid) including rack and cables |
Engine coolant heater |
Base frame design incorporates an integral fuel tank and anti-vibration isolators |
Flexible fuel connection hoses |
Single bearing, class H alternator |
Industrial exhaust silencer and steel bellows supplied separately(for open sets) |
Static battery charger |
Manual for application and installation |
Optional Equipments |
Engine |
• Fuel-Water Seperator Filter |
• Low water level alarm |
• Oil heater |
Alternator |
• Anti-Condensation Heater |
• Over sized alternator |
• Main line circuit breaker |
Control Panel |
• Remote annunciator panel |
• Remote relay output |
• Alarm output relays |
• Remote communication with modem |
• Earth fault, single set |
• Charge Ammeter |
ATS |
• Three or four pole contactor |
• Three or four pole motor operated circuit breaker |
Other |
• Trailer |
• Main Fuel Tank |
• Automatic or manual fuel filling system |
• Manual oil drain pump |
• Residential silencer |
• Enclosure: weater protective or sound attenuated |
• Duct adapter ( on radiator) |
• Inlet and outlet motorised louvers |
• Inlet and outlet acoustic baffles |
• Tool kit for maintenance |
• Supplied with oil and coolant – 30 °C |
• Battery isolating switch |